EUROSEGUR quality is certified by CIDEMCO Technology Research Center. Their doors have past the hardest and most stringent tests, exceeding real circumstances.
|
|
BurglaryBurglary Resistance: UNE-ENV-1627/1628/1629/1630 European Regulation Standards classify a security door resistance against attack from grade categories 1 to 6. Classifying grade 1 as the least resistant and grade 6 as the most strength resistant against attack. Since 2003 EUROSEGUR steel armoured doors have obtained GRADE 5 category in resistance against attack in every range (except Start and Alba ranges). EUROSEGUR is the first Spanish Company with Grade 5 in all their security steel armoured doors. This Norm is not obligatory in Spain (currently). But EUROSEGUR thinks that clients must know how to secure their doors when purchasing the door which best meet their needs. |
![]() |
Fire
Fire Resistance: UNE-EN 1634-1:2000 European Regulations classify doors resistance against fire. EUROSEGUR Alba range has obtained EI230C5, 30 minutes fire resistant. |
![]() |
Durability
Resistance to continuous opening and closing: UNE-EN 1191:2000 EUROSEGUR Alba Range fireproof doors and locks have a durability of 200,000 cycles (this result, although is not certified, can be applied to all the other ranges). |
|
|
Air TightAir Permeability : Testing UNE-EN 1026:2000 CLASS C3 (frame 105x45) The European Regulations classify doors from Class 1 to Class 4. A door with Class 4 is air tighter. |
|
|
Wind ResistanceWind Permeability: Testing UNE-EN 12211:2000 CLASS C4 (Frame 105x45) The European Regulation classify class C1 to C5. Being Class C5 the most resistant to wind. |
|
|
NoiseAcoustic Insulation: Testing UNE-EN ISO 140-3:1995 35 dB-38 dB (Frame 105x45) EUROSEGUR Steel Armoured Doors standard frame is 105x45, with a 35 dB reduction can reach up to 38 dB (optional), which is excellent for noise reduction from the exterior. |
|
|
Thermal InsulationThermal Insulation: Testing UNE-EN ISO 10077:2:200 Armoured Door Panel: 2,1 W/m2K (Frame 105x45) EUROSEGUR door panel with frame 105x45 presents a heat transfer coefficient of 2.1 W / m2K. This shows a good thermal insulation condition for this door. The CTE in its "Basic Document HE" states that the maximum value allowed for glass enclousures and frames should be up to 3.10 W / m2K. The value obtained here is only just below it. |
![]() |
CE MarkingCE Marking for windows and exterior doors: Testing UNE-EN 14351-1 CE marking is obligatory for Technical Product Declaration when marketing a product within the European Community. It is compulsory for exterior doors of public use from February 2010 . EUROSEGUR armoured doors contribute to make spaces more comfortable. They act as a barrier against air, water and wind and protect spaces from noise and cold. |